Clinical Pediatrics

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here for more information

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Easley, R. B.
Right arrow Articles by Tobias, J. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Easley, R. B.
Right arrow Articles by Tobias, J. D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Clinical Pediatrics, Vol. 41, No. 5, 351-355 (2002)
DOI: 10.1177/000992280204100508

Continuous pH Monitoring Using the Paratrend® 7 Inserted into a Peripheral Vein in a Patient with Shock and Congenital Lactic Acidosis

R. Blaine Easley, MD

Tiffanie R. Johnson, MD

Joseph D. Tobias, MD

Departments of Child Health and Anesthesiology, The University of Missouri, Columbia, Missouri

The authors present a 25-year-old woman who was admitted to the ICU for treatment of shock, respiratory failure, and acidosis related to congenital lactic acidosis from pyruvate dehydrogenase deficiency. To aid in ongoing management of the metabolic acidosis, the Paratrend® blood gas monitoring sensor was inserted through a peripheral venous site to provide a continuous measurement of pH and partial pressure of carbon dioxide (Pco2). With the venous insertion of the Paratrend®, a clinically useful correlation with arterial blood gas values was noted. Linear regression analysis of the pH values from the venous blood gas analyses and the Paratrend® monitor revealed r2 = 0.71 with p = 0.001 and r2 = 0.78 with a p = 0.0003 for the Pco2 values. Our preliminary experience suggests that venous placement of the Paratrend® monitor can be used to provide clinically useful, continuous measurement of pH and Pco2.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?