Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to register

Click here to browse AJSM online!

Sign In to gain access to subscriptions and/or personal tools.
Clinical Pediatrics
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Terndrup, T. E.
Right arrow Articles by Milewski, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Terndrup, T. E.
Right arrow Articles by Milewski, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

The Performance of Two Tympanic Thermometers in a Pediatric Emergency Department

Thomas E. Terndrup, MD, FACEP

Assistant Professor, Department of Emergency Medicine, SUNY Health Science Center, 750 E. Adams St., Syracuse, NY 13210

Anne Milewski, RN, BS

Research Associate, Department of Medicine; Division of Critical Care, State University of New York Health Science Center at Syracuse

In a prospective, unblinded, controlled study, 303 children underwent comparison of rectal (RT) and right-sided tympanic membrane (TMT) temperatures. Digital electronic thermometers were used for RT, while two different infrared detection devices assessed TMT. The performance of TMT devices were compared using correlation with RT, fever detection, and ease of use. Correlation between RT and the two devices was good, r = 0.70 and r = 0.69, with little influence of patient age on performance. Using receiver operating characteristics curves to assess fever screening. Thermoscan@ performed somewhat better than First Temp@. Staff rated the Thermoscan® as significantly easier to use.

Clinical Pediatrics, Vol. 30, No. 4 suppl, 18-23 (1991)